TDM/X Linear Actuator
Performance Specifications
| TDM/X060 Linear Actuator Performance Specifications | |||||
|---|---|---|---|---|---|
| Backlash | in (mm) | .004 (.10) | |||
| Lead Accuracy | in/ft (mm/300 mm) | .001 (.25) | |||
| Maximum Radial Load | lb (N) | 15 (67) | |||
| Environmental Rating: Std | IP54 Std / IP65 | ||||
| Stator | 1 Stack 1B8-50 | 2 Stack 2B8-50 | 2 Stack 2B8-40 | ||
| Lead | RPM @ 48 VDC | 5000 | 5000 | 4000 | |
| 0.1 | Continuous Stall Force | lbf (N) | 367 (1632) | 503 (2237) | NA |
| Peak Stall Force | ibf (N) | 734 (3265) | 829 (3688) | NA | |
| Max Speed @ 48 VDC | in/sec (mm/sec) | 8.33 (211.6) | 8.33 (211.6) | NA | |
| 0.2 | Continuous Stall Force | lbf (N) | 183 (814) | 251 (1117) | 327 (1455) |
| Peak Stall Force | ibf (N) | 367 (1632) | 415 (1846) | 465 (2068) | |
| Max Speed @ 48 VDC | in/sec (mm/sec) | 16.67 (423.4) | 16.67 (423.4) | 13.33 (338.6) | |
| 0.4 | Continuous Stall Force | lbf (N) | 92 (409) | 126 (560) | 163 (725) |
| Peak Stall Force | ibf (N) | 183 (814) | 207 (921) | 232 (1032) | |
| Max Speed @ 48 VDC | in/sec (mm/sec) | 33.33 (846.6) | 33.33 (846.6) | 26.67 (677.4) | |
| Drive Current @ Continuous Stall Force | Amps | 14.75 | 21.5 | 21.5 | |
| Available Stroke Lengths in (mm) | 3 (75), 6 (150), 10 (254), 12 (300) | ||||
| Approximate Weight lb (kg) | 4 lbs – 3 in stroke, 1 stack, add 1 lb per inch of stroke, add 3 lbs per stack, add 3 lbs for brake. (1.8 kg – 75 mm stroke, 1 stack, add 0.5 kg per 25 mm of stroke, add 1.4 kg per stroke, add 1.4 kg for brake.) | ||||
| Continuous AC Input Current* | Amps | 8.5 | 14.5 | 15 | |
Power supply current is based on software current limit, not thermal limit. Consideration for peak current should also be considered when sizing power supplies. | |||||
| Ratings based on 40°C conditions. | |||||
| TDM/X075 Linear Actuator Performance Specifications | |||||
|---|---|---|---|---|---|
| Backlash | in (mm) | .004 (.10) | |||
| Lead Accuracy | in/ft (mm/300 mm) | .001 (.25) | |||
| Maximum Radial Load | lb (N) | 15 (67) | |||
| Environmental Rating: Std | IP54 Std / IP65 | ||||
| Stator | 1 Stack 1B8-30 | 2 Stack 2B8-30 | 3 Stack 2B8-20 | ||
| Lead | RPM @ 48 VDC | 3000 | 3000 | 2000 | |
| 0.1 | Continuous Stall Force | lbf (N) | 653 (2905) | 955 (4248) | NA |
| Peak Stall Force | ibf (N) | 1106 (4920) | 1307 (5814) | NA | |
| Max Speed @ 48 VDC | in/sec (mm/sec) | 5.00 (127) | 5.00 (127) | NA | |
| 0.2 | Continuous Stall Force | lbf (N) | 327 (1455) | 478 (2126) | 754 (3354) |
| Peak Stall Force | ibf (N) | 553 (2460) | 653 (2905) | 1030 (4582) | |
| Max Speed @ 48 VDC | in/sec (mm/sec) | 10.00 (254) | 10.00 (254) | 6.67 (169.4) | |
| 0.5 | Continuous Stall Force | lbf (N) | 131 (583) | 191 (850) | 302 (1343) |
| Peak Stall Force | ibf (N) | 221 (983) | 261 (1161) | 412 (1833) | |
| Max Speed @ 48 VDC | in/sec (mm/sec) | 25.00 (635) | 25.00 (635) | 16.67 (423.4) | |
| Drive Current @ Continuous Stall Force | Amps | 18.5 | 22.5 | 22.5 | |
| Available Stroke Lengths in (mm) | 3 (75), 6 (150), 10 (254), 12 (300), 14 (355), 18 (450) | ||||
| Approximate Weight lb (kg) | 11 lbs – 3 in stroke, add 1 lb per inch of stroke, add 3 lbs per stack, add 3 lbs for brake | ||||
| Continuous AC Input Current* | Amps | 11 | 18 | 18 | |
| Power supply current is based on software current limit, not thermal limit. Consideration for peak current should also be considered when sizing power supplies. | |||||
| Ratings based on 40°C conditions. | |||||