T2M/X Linear Actuator Performance Specifications
| T2M/X090 Linear Actuator Performance Specifications | |||||
|---|---|---|---|---|---|
| Backlash | in (mm) | .008 (.20) | |||
| Lead Accuracy | in/ft (mm/300 mm) | .001 (.25) | |||
| Maximum Radial Load | lb (N) | 15 (67) | |||
| Environmental Rating: Std | IP54 Std / IP65 Optional on T2M | ||||
| Stator | 1 Stack 138-40 | 2 Stack 238-40 | 2 Stack 238-30 | ||
| Lead | RPM @ 240 VAC | 4000 | 4000 | 3000 | |
| 0.1 | Continuous Stall Force | lbf (N) | 1205 (5360) | 1587 (7059) | NA |
| Peak Stall Force | ibf (N) | 2411 (10725) | 3175 (14123) | NA | |
| Max Speed | in/sec (mm/sec) | 6.67 (169) | 6.67 (169) | NA | |
| 0.2 | Continuous Stall Force | lbf (N) | 603 (2682) | 794 (3532) | 1047 (4657) |
| Peak Stall Force | ibf (N) | 1205 (5360) | 1587 (7059) | 2094 (9315) | |
| Max Speed | in/sec (mm/sec) | 13.33 (338) | 13.33 (338) | 10.00 (254) | |
| 0.5 | Continuous Stall Force | lbf (N) | 241 (1072) | 317 (1410) | 419 (1864) |
| Peak Stall Force | ibf (N) | 482 (2144) | 635 (2825) | 838 (3728) | |
| Max Speed | in/sec (mm/sec) | 33.33 (846) | 33.33 (846) | 25.00 (635) | |
| Drive Current @ Continuous Stall Force | Amps | 5.7 | 7.5 | 7.5 | |
| Available Stroke Lengths in (mm) | 3 (75), 6 (150), 10 (254), 12 (300), 18 (450) | ||||
| Approximate Weight lb (kg) | 14 (6.35) 3" stroke, 1 stack | 1 (0.5) Added weight per inch of stroke | 3 (1.4) Added weight per motor stack | 3 (1.4) Added weight for brake | |
| Continuous AC Input Current* | Amps | 6.3 | 6.3 | 6.3 | |
| Continuous input current rating is defined by UL and CSA. | |||||
| Ratings based on 25°C conditions. | |||||
| T2M/X115 Linear Actuator Performance Specifications | |||||
|---|---|---|---|---|---|
| Backlash | in (mm) | .008 (.20) | |||
| Lead Accuracy | in/ft (mm/300 mm) | .001 (.25) | |||
| Maximum Radial Load | lb (N) | 15 (67) | |||
| Environmental Rating: Std | IP54 Std / IP65 Optional on T2M | ||||
| Stator | 1 Stack 138-30 | 2 Stack 238-20 | 2 Stack 238-15 | ||
| Lead | RPM @ 240 VAC | 3000 | 2000 | 1500 | |
| 0.1 | Continuous Stall Force | lbf (N) | 2354 (10470) | 3685 (16391) | NA |
| Peak Stall Force | ibf (N) | 4709 (20947) | 7370 (32783) | NA | |
| Max Speed | in/sec (mm/sec) | 5.00 (127) | 3.33 (84) | NA | |
| 0.2 | Continuous Stall Force | lbf (N) | 1177 (5235) | 1843 (8198) | 2380 (10586) |
| Peak Stall Force | ibf (N) | 2354 (10471) | 3685 (16392) | 4760 (21174) | |
| Max Speed | in/sec (mm/sec) | 10.00 (254) | 6.67 (169) | 5.00 (127) | |
| 0.5 | Continuous Stall Force | lbf (N) | 471 (2095) | 737 (3278) | 952 (4234) |
| Peak Stall Force | ibf (N) | 942 (4190) | 1474 (6557) | 1904 (8469) | |
| Max Speed | in/sec (mm/sec) | 25.00 (635) | 16.67 (423) | 12.50 (317) | |
| 0.75 | Continuous Stall Force | lbf (N) | 314 (1397) | 491 (2184) | 635 (2825) |
| Peak Stall Force | ibf (N) | 628 (2793) | 982 (4368) | 1370 (6094) | |
| Max Speed | in/sec (mm/sec) | 37.5 (953) | 25 (635) | 18.75 (476) | |
| Drive Current @ Continuous Stall Force | Amps | 8.5 | 8.5 | 8.5 | |
| Available Stroke Lengths in (mm) | 6 (150), 10 (254), 12 (300), 18 (450) | ||||
| Approximate Weight lb (kg) | 34 (15.5) 6" stroke, 1 stack | 2 (1) Added weight per inch of stroke | 8 (4) Added weight per motor stack | 4 (2) Added weight for brake | |
| Continuous AC Input Current* | Amps | 8.3 | 8.3 | 8.3 | |
| Continuous input current rating is defined by UL and CSA. | |||||
| Ratings based on 25°C conditions. | |||||