AAABBB-CCDD-EFG-HH-III-II-JJJ-KKK - (XX..XX - #####)
AAA = Actuator Type HH = Feedback Type
TDM = Tritex II Linear Actuator, standard mechanical capacity HD = Analog Hall Device
TDX = Tritex II Linear Actuator, high mechanical capacity IE = Incremental Encoder, 8192 count resolution
BBB = Actuator Frame Size AF = Absolute Feedback
060 = 60 mm III-II = Motor Stator, All 8 Pole
075 = 075 mm TDM/X060
CC = Stroke Length (nominal) 1B8-50 = 1 stack, 48 VDC, 5000 rpm
03 = 3 inch (75 mm)
2B8-50 = 2 stack, 48 VDC, 5000 rpm

06 = 6 inch (150 mm)

10 = 10 inch (250 mm)

3B8-40 = 3 stack, 48 VDC, 4000 rpm 4
12 = 12 inch (305 mm) TDM/X075
14 = 14 inch (355 mm) (75mm only)
1B8-30 = 1 stack, 48 VDC, 3000 rpm
18 = 18 inch (455 mm) (75mm only)
2B8-30 = 2 stack, 48 VDC, 3000 rpm
DD = Lead (linear travel per screw revolution) 3B8-20 = 3 stack, 48 VDC, 2000 rpm 4
01 = 0.1 inch (2.54 mm)4 JJJ = Voltage
02 = 0.2 inch (5.08 mm) 048 = 12-48 VDC
04 = 0.4 inch (10.16 mm) (60 mm only)
KKK = Option  Board
05 = 0.5 inch (12.7 mm) (75 mm only)
SIO = Standard I/O Interconnect
E = Connections IA4 = SIO plus isolated 4-20mA Analog I/O
G = Standard straight threaded port with internal terminals, M20x1.5 (75 mm only)
EIP = SIO plus EtherNet IP
N = NPT threaded port via adapter with Internal terminals, 1/2" NPT (75 mm only)
TCP = SIO plus Modbus TCP/IP
I = Intercontec style - Exlar std, M23 style connector. X..XX = Travel and Housing Options (Multiple Possible)
X = Special (please specify) Travel Options
F = Mounting AR = External Anti-rotate
F = Front Flange PF = Preloaded Follower 2
R = Rear Flange L1/2/3 = External Limit Switches 6
S = Side Mount RB = Rear Brake
J = Metric Side Mount SD = Side Manual Drive
B = Front & Rear Flange ET = External Linear Transducer
C = Rear Clevis HW = Manual Drive Handwheel with limit switch
G = Metric Rear Clevis PB = Protective Bellows 8
T = Side Trunnion SR = Splined Main Rod 7
Q = Metric Side Trunnion XT = Special Travel Options
E = Extended Tie Rod Special Motor Options
M = Metric Extended Tie Rod XL = Special Lubrication Option 5
D = Double Side Mount XM = Special Motor Option
K = Metric Double Side Mount XH = Special Housing Option
X = Special Housing Options
G = Rod End P5 = IP65 sealed housing (TDM only) 
M = Male US Standard Thread 1 HC = Type III Hard Coat Anodized 3
A = Male Metric Thread 1 FG = Smooth White Epoxy Coating 3
F = Female US Standard Thread 1 XH = Special Housing Option
B = Female Metric Thread 1 ##### = Part Number Designator for Specials
W = Male, US Standard Thread 17-4 SS Optional 5 digit assigned PN to designate unique model numbers
R = Male Metric Thread 17-4 SS
V = Female US Standard Thread 17-4 SS
L = Female Metric Thread 17-4 SS  
X = Special (please specify)
Notes:
1. Chrome-plated carbon steel. Threads not chrome-plated.
2. The dynamic load rating of zero backlash, preloaded screws is 63% of the dynamic load rating of the std non-preloaded screws. The calculated travel life of a preloaded screw will be 25% of the calculated travel life of the same size and lead of a non-preloaded screw.
3. This housing option may indidate the need for special material main rods or mounting.
4.  N/A with 0.1 inch lead, N/A on 3 inch stroke.
5. To achieve -40 operating temperature, specify -XL in the actuator model mask and define Mobilgrease 28 in order notes. Other special lubricants are also available.
6. Limit switch option requires AR option.
7. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
8. Not available with extended tie rod mounting option.