Tritex

Simplify your motion applications

Tritex II™ AC Posered Linear and Rotary Actuators With Enbedded Electronics

Linear Actuator Ordering Guide

TRITEX II T2M/X LINEAR ACTUATOR ORDERING GUIDE
T2M/XBBB-CCDD-EFG-HH-III-II-JJJ-KKK- (XX..XX - #####)
T2M/X = Actuator Type III-II = Motor Stator, All 8 Pole
T2M = Tritex II Linear Actuator, standard mechanical capacity T2M/X090 Stator Specifications
T2X = Tritex II Linear Actuator, high mechanical capacity 138-40 = 1 Stack, 230 VAC, 4000 rpm
BBB = Actuator Frame Size 238-40 = 2 Stack, 230 VAC, 4000 rpm
090 = 90 mm 238-30 = 2 Stack, 230 VAC. 3000 rpm (10)
115 = 115 mm T2M/X115 Stator Specifications H
CC = Stroke Length 138-30 = 1 Stack, 230 VAC, 3000 rpm
03 = 3 inch (75 mm) (T2M/X090 only) 238-20 = 2 Stack, 230 VAC, 2000 rpm
06 = 6 inch (150 mm) 238-15 = 2 Stack, 230 VAC, 1500 rpm
10 = 10 inch (250 mm) JJJ = Voltage
12 = 12 inch (305 mm) 230 = 115-230 VAC, single phase
18 = 18 inch (455 mm) KKK = Option Board
DD = Lead (linear travel per screw revolution) SIO = Standard I/O Interconnect
01 = 0.1 inch (2.54 mm) IA4 = SIO plus Isolated 4 - 20 mA Analog I/O
02 = 0.2 inch (5.08 mm) EIP = SIO plus Ethernet IP
05 = 0.5 inch (12.7 mm) ABZ = SIO plus encoder output signal, requires IE Feedback option. Includes M12 connector for encoder output signals. (2)
08 = 0.75 inch (19.05 mm) (T2M/X115 only) (5) TCP = Modbus TCP
E = Connections X..XX = Travel and Housing Options (Multiples Possible)
G = Standard Straight Threaded Port with Internal terminals, M20x1.5 Travel Options
AR = External Anti-rotate
N = NPT Threaded Port via Adapter with Internal Terminals, 1/2” NPT PF = Preloaded Follower (3)
L1/2/3 = External Limit Switches (7)
I = Intercontec style - Exlar std, M16/M23 Style Connector RB = Rear Brake
X = Custom Connectivity XT = Special Travel Options
F = Mounting Housing Options
B = Front & Rear Flange F = Front Flange P5 = IP65 sealed housing (T2M only)
C = Rear Clevis R = Rear Flange HC = Type III Hard Coat Anodized (4)
G = Metric Rear Clevis S = Side Mount FG = Smooth White Epoxy Coating (4)
D = Double Side Mount J = Metric Side Mount Special Motor Options
K = Metric Double Side Mount T = Side Trunnion HW = Manual Drive Hand Wheel (T2X only)
SD = Side Manual Drive
HV = High Vibration Option-EIC (9)
ET = External Linear Transducer
XL = Special Lubrication (6)
XM = Special Motor Option
XH = Special Housing Option
XT = Manual Drive Hand Wheel (T2X only)
XT = Protective Bellows (N/A with Extended tie rod mounting option)
XT = Splined Main Rod (8)
E = Extended Tie Rod Q = Metric Side Trunnion
M = Metric Extended Tie Rod X = Special
G = Rod End
M = Male US Standard Thread (1)
A = Male Metric Thread (1)
F = Female US Standard Thread(1) ##### = Part Number Designator for Specials
B = Female Metric Thread (1) Optional 5 digit assigned PN to designate unique model numbers
W = Male, US Std Thread 17-4 SS Notes:
R = Male Metric Thread 17-4 SS (1) Chrome-plated carbon steel. Threads not chrome-plated.
V = Female US Standard Thread 17-4 SS (2) Will require external cable for encoder output signals
L = Female Metric Thread 17-4 SS (3) The dynamic load rating of zero backlash, preloaded screws is 63% of the dynamic load rating of the std non-preloaded screws. The calculated travel life of a preloaded screw will be 25% of the calculated travel life of the same size and lead of a non-pre loaded screw.
X = Special (please specify)
HH = Feedback Type
HD = Analog Hall Device (4) This housing option may indidate the need for special material main rods or mounting.
IE = Incremental Encoder, 8192 count resolution
AF = Absolute Feedback (5) 0.75 lead not available above 12” stroke.
(6) To achieve -40 operating temperature, specify -XL in the actuator model mask and define Mobilgrease 28 in order notes. Other special lubricants are also available.
(7) Limit switch option requires AR option.
(8) This option is not sealed and is not suitable for any environment in which contaminants come in contact with actuator and may enter the actuator.
(9) EIC 60068-2-64 2.5g, 50-500 Hz.
(10) N/A with 0.1" lead